TAD950VE, TAD951VE, TAD952VE
Parameter Alarm Engine protection
Setting range Default setting Derating level Action
Oil temperature 120-130 °C
(248-266 °F)
125 °C
(257 °F)
Setting +3 °C
(5.4 °F)
Torque reduction
Oil pressure Low idle NA 160 kPa
(23.2 psi)
140 kPa
(20.3 psi)
Torque reduction
Rated speed NA 200 kPa
(29.0 psi)
180 kPa
(26.1 psi)
Torque reduction
Oil level NA Low level NA NA
Piston cooling pressure,
>1000 rpm
NA NA NA Torque reduction
Coolant temperature 95-101 °C
(203-213.8 °F)
98 °C
(208.4 °F)
Setting +3 °C
(5.4 °F)
Torque reduction
Coolant Level - On Low level Torque reduction
Fuel feed pressure Low idle NA 100 kPa
(14.5 psi)
NA NA
Water in Fuel Water present NA NA NA
Crankcase Pressure Rapid pressure
increase
- - Torque reduction
Air filter pressure droop NA NA NA NA
Altitude, above sea NA NA 1200 m
(1312 yds)
Automatic derating
Intake manifold temperature NA 80 °C
(176 °F)
91 °C
(195.8 °F)
Torque reduction
Air inlet pressure NA 325 kPa
(47.1 psi)
350 kPa
(50.8 psi)
Torque reduction
Engine Speed 100-120 % of
rated speed
115 % of rated
speed
Alarm level
Shutdown. On/Off
(1)
1. Off = No shutdown, alarm only.
03-3 Specifications, Electrical
8 47701632 10-2013 © AB VOLVO PENTA