MID 128, PID 175 Engine oil
temperature
FMI 0 – Data valid but above normal operational range
Fault code explanation: Engine oil temperature too high.
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 3.7
Value fault: 5.8
Symptom: Power is reduced due to error torque map if the engine protection parameter
is activated.
Conditions for fault code: Engine oil temperature is too high.
Suitable action: 1 Check the oil level in the engine.
2
Check the coolant level and the engine temperature.
3
Check that no leakage occurs.
4 Check the sensor.
5 Clean the oil cooler system and check the bypass valve for the oil
cooler.
Please refer to more detailed instructions in the “Workshop manual group 22,
Lubrication system”.
FMI 4 – Voltage below normal or shorted to lower voltage
Fault code explanation: Faulty sensor / Fault in sensor circuit
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 3.7
Value fault: 5.8
Conditions for fault code: The voltage on pin A31 in the engine control unit is less than 0.07 Volt.
Possible reason: Short circuit between the oil temperature signal cable to the sensor
negative cable.
Short circuit between the oil temperature signal cable and the sensor
5V supply cable.
Short circuit between oil temperature signal cable and oil level signal
cable.
Fault in sensor.
Suitable action: 1 Check the cable harness between the sensor and the EMS2.
2 Check the sensor.
30-2 Fault Tracing
47701632 10-2013 © AB VOLVO PENTA 99

دیزل ژنراتور | ماشین های راهسازی | لودر | بیل مکانیکی | لیفتراک | موتور پمپ | پمپ آب