TAD940GE, TAD941GE
Parameter Alarm Engine protection
Setting range Default setting Derating level Action
Oil temperature 120-130 °C
(248-266 °F)
125 °C
(257 °F)
Setting +3
(5.4 °F)
Shutdown. On/Off
Oil pressure Low idle NA 160 kPa
(23.2 psi)
130 kPa
(18.9 psi)
Shutdown. On/Off
1500 rpm NA 250 kPa
(36.3 psi)
220 kPa
(31.9 psi)
Shutdown. On/Off
1800 rpm NA 300 kPa
(43.5 psi)
270 kPa
(39.2 psi)
Shutdown. On/Off
Oil level NA Low level NA NA
Piston cooling pressure,
>1000 rpm
NA NA NA NA
Coolant temperature 95-103 °C
(203-217.4 °F)
98 °C
(208.4 °F)
Setting +5
(9 °F)
Shutdown. On/Off
Coolant Level NA Low level Low level Shutdown. On/Off
Fuel feed pressure Low idle NA 150 kPa
(21.8 psi)
NA NA
>1400 rpm NA 300 kPa
(43.5 psi)
NA NA
Water in Fuel NA Water in Fuel NA NA
Crankcase Pressure NA Increased pres-
sure
Increased pres-
sure
Shutdown. On/Off
Air filter pressure droop NA NA NA NA
Altitude, above sea NA - >1500 m
(>1640 yds)
Automatic derating
Intake manifold temperature NA 87 °C
(188.6 °F)
92 °C
(197.6 °F)
Shutdown. On/Off
Air inlet pressure NA 380 kPa
(55.1 psi)
380 kPa
(55.1 psi)
Shutdown. On/Off
Engine Speed 100-120 % of
rated speed
120 % of rated
speed
Alarm level Shutdown. Off/On