MID 128, SID 21 Engine position
FMI 2 – Data erratic, intermittent or incorrect
Fault code explanation: Faulty sensor / Faulty sensor circuit
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 2.5
Value fault: None.
Symptom: The engine start time will increase, uses only crankshaft sensor.
Conditions for fault code: Incorrect timing.
Possible reason: Polarity fault. The cables to the cam speed sensor is shifted.
Intermittent fault.
Incorrectly mounted cam speed sensor.
Suitable action: 1 Check the cable harness between the cam speed sensor and EMS2.
2 Check that the cam speed sensor is connected as in the circuit descrip-
tion.
3 Check the cam speed sensor.
FMI 3 – Voltage above normal or shorted high
(No signal)
Fault code explanation: Faulty sensor / Faulty sensor circuit
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 2.5
Value fault: None.
Symptom: The engine start time will increase, uses only crankshaft sensor.
Conditions for fault code: No camsignal when expected.
Possible reason: Incorrectly mounted cam speed sensor.
Open circuit in any or both of the cables to the crank speed sensor.
Short circuit between the cables to the cam speed sensor.
Faulty cam speed sensor.
Suitable action: 1 Check the installation of the cam speed sensor.
2 Check the cable harness between the cam speed sensor and EMS2.
3 Check the cam speed sensor.
4 Check the contact pressure in socket 45 and 46 in engine connector A.
30-2 Fault Tracing
47701632 10-2013 © AB VOLVO PENTA 121