MID 128, SID 22 Timing sensor,
crank
FMI 2 – Data erratic, intermittent or incorrect
Fault code explanation: Faulty sensor / Faulty sensor circuit
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 2.4
Value fault: None.
Symptom: Engine is difficult to start, uses only cam sensor.
Conditions for fault code: Incorrect signal.
Possible reason: Short circuit between the cables to the flywheel sensor.
Polarity fault. The cables to the flywheel sensor is shifted.
Suitable action: 1
Check the cable harness between the flywheel sensor and EMS2.
2 Check that the flywheel sensor is connected as in the circuit description.
3 Check the flywheel sensor.
FMI 3 – Voltage above normal or shorted high
(No signal)
Fault code explanation: Faulty sensor / Faulty sensor circuit
Fault indication: DCU: Engine warning in DCU display.
CIU: Flash code
Flash code
Electrical fault: 2.4
Value fault: None.
Symptom: Engine is running with imprecise timing causing risk of high fuel consumption
and smoke. Cylinder balancing not working with risk of uneven running.
Conditions for fault code: No cranksignal when expected or permanent loss of sensor signal.
Possible reason: Open circuit in any or both of the cables to the flywheel sensor.
Incorrectly mounted flywheel sensor.
Faulty flywheel sensor.
Suitable action: 1 Check the cable harness between the flywheel sensor and EMS2.
2 Check the installation of the flywheel sensor.
3 Check the flywheel sensor.
4 Check the contact pressure in socket 37 and 38 in engine connector A.
30-2 Fault Tracing
47701632 10-2013 © AB VOLVO PENTA 123

دیزل ژنراتور | ماشین های راهسازی | لودر | بیل مکانیکی | لیفتراک | موتور پمپ | پمپ آب