
Checking negative cable, oil
pressure sensor
Tools:
885675 Break-out cable
88890074 Multimeter
1 NOTICE! Cut the current with the main switch.
2 Disconnect the connector from the sensor
3
Connect break-out cable 885675 to the cable har-
ness connector to the engine control unit.
4 Use multimeter 88890074 to do resistance meas-
urement against the engine control unit.
Measurement points Nominal value
4 – Battery negative R ≈ 0 Ω
Checking signal cable, oil pressure
sensor
Tools:
885675 Break-out cable
88890074 Multimeter
1 NOTICE! Cut the current with the main switch.
2 Disconnect the connector from the sensor
3
Connect break-out cable 885675 to the cable har-
ness connector to the engine control unit.
4 Use multimeter 88890074 to do resistance meas-
urement against the engine control unit.
Measurement points Nominal value
2–4 R ≈ 80 – 120 kΩ
NOTICE! Measurement is done to eliminate short cir-
cuiting
or
breaks in the cable to the engine control unit.
30-2 Fault Tracing
148 47701632 10-2013 © AB VOLVO PENTA