TAD1350VE
Parameter Signal Parameter
range
Alarm
switch
Alarm
level
Derating level Condi-
tion /
delay
Derating
Oil temperature 50-0 kW -40°–140 °C
(-40–284 °F)
- 125 °C
(257 °F)
130 °C
(266 °F)
2 s 100% of
max torque
Oil level - - - Low level N/A 30 s -
Air inlet pres-
sure
0,5-4,5 V 50-400 kPa
(7.3-58 psi)
- - 10 kPa above
alarm level
2 s 50% of max
torque
Intake manifold
temperature
50-0 kW -40°–130 °C
(-40–266 °F)
- 82 °C
(179.6 °F)
87 °C
(188.6 °F)
30 s 100% of
max torque
Crankcase Pres-
sure
0,5-4,5 V 0-15 kPa
(0-2.2 psi)
- Rapid
pressure
increase
Rapid pres-
sure increase
Instant 100% of
max torque
Water in Fuel Digital - Alarm
when
closed
Water in
Fuel
N/A 5 s N/A
Coolant temper-
ature
50-0 kW -40°–140 °C
(-40–284 °F)
- 102 °C
(215.6 °F)
107 °C
(224.6 °F)
2 s 50% / °C of
max torque
Coolant level Digital - Alarm
when
closed
Low level N/A 4 s N/A
Engine speed,
camshaft
Frequency - - Lost signal - Instant -
Engine speed,
crankshaft
Frequency - - Lost signal - Instant -
Parameter Signal Parameter
range
Engine speed Condi-
tion
Derating
Fuel pres-
sure
0,5-4,5 V 0-700 kPa
(0-101 psi)
600 rpm 1000
rpm
1200
rpm
1500
rpm
1900
rpm
- -
Warning
level
- - 0 100 150 200 200 5 s N/A
Alarm level - - N/A N/A N/A N/A N/A N/A N/A
Oil pres-
sure
0,5-4,5 V 0-700 kPa
(0-101 psi)
600 rpm 1000
rpm
1200
rpm
1500
rpm
1900
rpm
- -
Warning
level
- - 140 200 224 260 287 2 s -
Alarm level - - 115 175 199 235 262 Instant 70% of
max torque
in step of
10% / s
03-3 Specifications, Electrical
14 47701632 10-2013 © AB VOLVO PENTA

دیزل ژنراتور | ماشین های راهسازی | لودر | بیل مکانیکی | لیفتراک | موتور پمپ | پمپ آب