1–2 R ≈ 454 Ω
at 350° C
U ≈ 1.56 V
at 350° C
1–2 R ≈ 488 Ω
at 400° C
U ≈ 1.64 V
at 400° C
1–2 R ≈ 521 Ω
at 450° C
U ≈ 1.71 V
at 450° C
1–2 R ≈ 554 Ω
at 500° C
U ≈ 1.78 V
at 500° C
1–2 R ≈ 618 Ω
at 600° C
U ≈ 1.91 V
at 600° C
1–2 R ≈ 679 Ω
at 700° C
U ≈ 2.02 V
at 700° C
1–2 R ≈ 738 Ω
at 800° C
U ≈ 2.12 V
at 800° C
1–2 R ≈ 795 Ω
at 900° C
U ≈ 2.21 V
at 900° C
1–2 R ≈ 849 Ω
at 1000° C
U ≈ 2.30 V
at 1000° C
Checking negative cable, oil
temperature switch
Tools:
885675 Break-out cable
88890074 Multimeter
1 NOTICE! Cut the current with the main switch.
2 Disconnect the connector from the sensor
3
Connect break-out cable 885675 to the cable har-
ness connector to the engine control unit.
4 Use multimeter 88890074 to do resistance meas-
urement against the engine control unit.
Measurement points Nominal value
4 – Battery negative R ≈ 0 Ω
885675
2
3
4
5
1
4
P0013506
30-2 Fault Tracing
47701632 10-2013 © AB VOLVO PENTA 165