TAD1360VE, TAD1361VE, TAD1362VE,
TAD1363VE, TAD1364VE, TAD1365VE,
TAD1640VE-B, TAD1641VE-B, TAD1642VE-B,
TAD1660VE, TAD1661VE, TAD1662VE
Parameter Warning level Alarm level Engine protection
Parameter for Power Pack Default setting Level Action.
Default / Alternative
Oil temperature 125 °C (257 °F) Setting +5 °C (9 °F)
Shutdown. On/Off
(1)
Oil pressure Low idle 50 kPa (7.3 psi) 25 kPa (3.6 psi)
Shutdown. On/Off
(1)
Rated speed 300 kPa (43.5 psi) 275 kPa (39.9 psi)
Shutdown. On/Off
(1)
Oil level Min level - -
Coolant temperature 105 °C (221 °F) 107 °C (224.6 °F)
Shutdown. On/Off
(1)
Coolant Level Low level - -
Fuel feed pressure Low idle - 100 kPa (14.5 psi) -
1200 rpm - 250 kPa (36.3 psi) -
Water in Fuel High level - -
Crankcase Pressure Increased pressure -
Shutdown. On/Off
(1)
Air filter pressure droop 5.0 kPa (0.7 psi) - -
Altitude, above sea - - Automatic derating
Intake manifold temperature 80 °C (176 °F) 85 °C (185 °F)
Shutdown. On/Off
(1)
Air inlet pressure Warning map value + 5
kPa (0.7 psi)
Alarm map value + 5
kPa (0.7 psi)
Shutdown. On/Off
(1)
Engine Speed 120 % -
Shutdown. On/Off
(1)
1. Off = Disables the function, i.e. no shutdown.
03-3 Specifications, Electrical
16 47701632 10-2013 © AB VOLVO PENTA