TAD1650VE
Parameter “Yellow
lamp”
“Red
lamp”
Derate 0 % to
eng. prot. map
Derate 70 %
to eng.
prot. map
Forced
idle after
5 sec
Forced shut-
down after 15
sec
Coolant temperature 98 °C
(208.4 °F)
101 °C
(213.8 °F)
101 °C
(213.8 °F)
106 °C
(222.8 °F)
>106 °C
(222.8 °F)
>106 °C
(222.8 °F)
Oil temperature 125 °C
(257.0 °F)
128 °C
(262.4 °F)
128 °C
(262.4 °F)
135 °C
(275.0 °F)
- -
High inlet manifold temper-
ature
80 °C
(176.0 °F)
83 °C
(181.4 °F)
83 °C
(181.4 °F)
90 °C
(194 °F)
>90 °C
(194 °F)
>90 °C
(194 °F)
Parameter “Yellow
lamp”
“Red lamp” Derate 50 % to eng.
prot. map
Forced idle
after 5 sec
Forced shut-
down after 15
sec
High air inlet pressure 30 kPa >
demand
(4.4 psi)
40 kPa >
demand
(5.8 psi)
40 kPa > demand
(5.8 psi)
45 kPa >
demand
(6.5 psi)
45 kPa > demand
(6.5 psi)
Parameter “Yellow
lamp”
“Red lamp” Derate 70 % to eng.
prot. map
Forced idle
after 5 sec
Forced shut-
down after 15
sec
Low Oil Pressure Limit 20 kPa <
limit
(2.9 psi)
20 kPa < limit
(2.9 psi)
25 kPa <
limit
(3.6 psi)
25 kPa < limit
(3.6 psi)
Low coolant level Switch - - - -
Low oil level Switch - - - -
Low piston cooling pres-
sure
- Switch <
150 kPa
(21.8 psi)
Switch < 150 kPa
(21.8 psi)
Switch <
150 kPa
(21.8 psi)
Switch < 150 kPa
(21.8 psi)
Crankcase Pressure - Rapid pres-
sure
increase
Rapid pressure
increase
Rapid pres-
sure
increase
Rapid pressure
increase
Oil pressure limit
x Engine speed
y Oil pressure
z Oil pressure limit
03-3 Specifications, Electrical
47701632 10-2013 © AB VOLVO PENTA 19