TAD1640GE, TAD1641GE, TAD1642GE
Parameter Alarm Engine protection
Setting range Default setting Derating level Action
Oil temperature 120-130 °C
(248-266 °F)
125 °C
(257 °F)
Setting +5
(9 °F)
Shutdown / Off
(1)
Oil pressure Low idle,
900 rpm
- 190 kPa
(27.6 psi)
160 kPa
(23.2 psi)
Shutdown / Off
(1)
1500 rpm - 250 kPa
(36.3 psi)
220 kPa
(31.9 psi)
Shutdown / Off
(1)
1800 rpm - 300 kPa
(43.5 psi)
270 kPa
(39.2 psi)
Shutdown / Off
(1)
Oil level - Min level - -
Piston cooling pressure,
>1000 rpm
- 150 kPa
(21.8 psi)
150 kPa
(21.8 psi)
Shutdown / Off
(1)
Coolant temperature 95-101 °C
(203-213.8 °F)
98 °C
(208.4 °F)
Setting +5
(9 °F)
Shutdown / Off
(1)
Coolant Level - On Low level
Shutdown / Off
(1)
Fuel feed pressure Low idle,
900 rpm
- 150 kPa
(21.8 psi)
- -
>1400 rpm - 300 kPa
(43.5 psi)
- -
Water in Fuel - High level - -
Crankcase Pressure - - - Shutdown
Air filter diff. pressure - 5.0 kPa (0.7 psi) - -
Altitude, above sea - - >1500 m
(>1640 yds)
Automatic derating
Intake manifold temperature - 80 °C
(176 °F)
85 °C
(185 °F)
Shutdown
(2)
Air inlet pressure - 290 kPa
(42.1 psi)
300 kPa
(43.5 psi)
Shutdown
(2)
Overspeed 100-120 % of
rated speed
120 % / Off
(1)
Alarm level
Shutdown / On
(3)
Low voltage - 25.5 V - -
1. Off = No shutdown, alarm only. (Only TAD1640-41GE).
2. Only TAD1640-41GE.
3. On = Only TAD1640-41GE.
03-3 Specifications, Electrical
20 47701632 10-2013 © AB VOLVO PENTA