TAD1641VE, TAD1642VE, TAD1643VE
Parameter Alarm Engine protection
Setting range Default setting Derating level Action
Oil temperature 120-130 °C
(248-266 °F)
125 °C
(257 °F)
Setting +5
(9 °F)
Shutdown / Off
(1)
Oil pressure Low idle - 160 kPa
(23.2 psi)
130 kPa
(18.9 psi)
Shutdown / Off
(1)
Rated speed - 300 kPa
(43.5 psi)
270 kPa
(39.2 psi)
Shutdown / Off
(1)
Oil level - Min level - -
Piston cooling pressure,
>1000 rpm
- 150 kPa
(21.8 psi)
150 kPa
(21.8 psi)
Shutdown / Off
(1)
Coolant temperature 95-101 °C
(203-213.8 °F)
98 °C
(208.4 °F)
Setting +5
(9 °F)
Shutdown / Off
(1)
Coolant Level - On Low level
Shutdown / Off
(1)
Fuel feed pressure Low idle - 100 kPa
(14.5 psi)
- -
Rated speed - 300 kPa
(43.5 psi)
- -
Water in Fuel - High level - -
Crankcase Pressure - - - Shutdown
Air filter pressure droop - 5.0 kPa (0.7 psi) - -
Altitude, above sea - - - Automatic derating
Intake manifold temperature - 80 °C
(176 °F)
85 °C
(185 °F)
Shutdown
Air inlet pressure - 290 kPa
(42.1 psi)
340 kPa
(49.3 psi)
Shutdown
Engine Speed 100-120 % of
rated speed
120 % / Off
(1)
Alarm level Shutdown / On
Low voltage - 25.5 V - -
1. Off = No shutdown, alarm only.
03-3 Specifications, Electrical
18 47701632 10-2013 © AB VOLVO PENTA