Group 23 EMS 2 Limit values
23
Limit values, control module (EMS 2) TAD1641–1643VE, TAD1650VE
Oil temperature
NOTE: The engine protection can be turned off.
Preset alarm limit Adjustable between Alarm lamp is lit Torque limitation Engine cut off
125 °C (257 °F) 120 - 130 °C at alarm limit no +5 °C (+41 °F)
(248 - 266 °F)
Oil pressure
NOTE: The engine protection can be turned off.
Preset alarm limit Adjustable between Alarm lamp is lit Torque limitation Engine cut off
See diagram oil pressure not adjustable at alarm limit max 900 Nm -30 kPa (-4,35 Psi)
below. (664 lbf-ft) at
alarm limit
Oil level
Preset alarm limit Adjustable between Alarm lamp is lit Torque limitation Engine cut off
low oil level not adjustable low oil level no no
Coolant temperature
NOTE: The engine protection can be turned off.
Preset alarm limit Adjustable between Alarm lamp is lit Torque limitation Engine cut off
98 °C (208 °F) 95 -103 °C at alarm limit no +5 °C (+41 °F)
(203 - 217,4 °F)
Oil pressure